FRP Rebar (Fiberglass Reinforcing Bar, Style 01)

FRP Rebar ( Fiberglass rebar style 01 )
  • FRP Rebar
  • Fiberglass rebar
  • FRP Rebar

FRP Rebar (Fiberglass Reinforcing Bar, Style 01)

Also called GFRP Rebar or Composite Rebar, FRP Rebar is a spiral-wound rod of glass fiber and resin engineered to outperform steel in concrete reinforcement. It suits structural and construction work that calls for light weight, high strength, corrosion resistance, and non-conductivity.

Customized service:

Diameter Color Length
Winding method Surface Sandblasting Punch hole

DescribeSolutionsFAQContact us

frp rebar machine

Why FRP Rebar Outperforms Steel: The Case for Glass Fiber Reinforced Plastic Rebar

Made by spiral-winding glass fiber and resin into a solid rod, FRP Rebar — also called GFRP Rebar (Glass Fiber Reinforced Plastic Rebar) or Composite Rebar — is a concrete reinforcement material built to outperform steel rebar. It suits structural and construction work that calls for light weight, high strength, corrosion resistance, and non-conductivity.

Key benefits of FRP Rebar:

Light weight: FRP Rebar’s specific gravity runs only one-fourth that of steel rebar, meaning it weighs just 25% as much as steel rebar of the same size. That trims the self-weight of concrete structures, lowers transport and installation costs and labor, and speeds up construction.

High strength: FRP Rebar’s tensile strength is twice that of steel rebar, so it withstands greater tension at the same diameter. This lowers the risk of cracking in concrete structures and increases their load-bearing capacity and safety.

Corrosion resistance: Unlike steel rebar, FRP Rebar is unaffected by water, chlorine, salt, acid, alkali, and other chemicals, letting it hold its performance and lifespan in harsh environments. This cuts maintenance and repair costs and extends the service life of structures.

Non-conductivity: FRP Rebar neither conducts electricity nor becomes magnetized the way steel rebar does, so it can be used in sensitive settings involving high voltage, high frequency, or electromagnetic interference. This avoids electric shock or signal interference and keeps concrete structures functional and stable.

Main parameters of FRP Rebar:

Diameter (mm) 6 8 10 12 14 16 18 20 22 25 28 30 32 34 36
Cross section(mm2) 28 50 73 103 134 180 248 278 355 478 590 671 740 867 977
Density (g/cm3) 2.2 2.2 2.2 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1
Weight (g/m) 51 98 150 210 275 388 485 570 700 970 1195 1350 1589 1788 2044
Ultimate Tensile Load (KN) 36 54 72 99 117 149 189 225 270 342 432 475 504 540 585
Ultimate Tensile Strength (Mpa) 1280 1080 980 870 764 752 744 716 695 675 702 637 626 595 585
Ultimate Shear Strength (Mpa) >150 >150 >150 >150 >150 >150 >150 >150 >150 >150 >150 >150 >150 >150 >150
E-modulus (GPa) >40 >40 >40 >40 >40 >40 >40 >40 >40 >40 >40 >40 >40 >40 >40

Interested in our FRP Rebar products? Contact us for more information and a quotation. Guangdong Haikuo Composite Materials Co.,Ltd. is a professional manufacturer and supplier of FRP Rebar across a wide range of specifications and performance grades.

Our contact number is +8618951988522, contact email is: [email protected].

We look forward to working with you and providing quality products and service.

Technical Summary & Engineering Insights

Executive Summary: Haikuo FRP Rebar is a spiral-wound glass fiber and resin reinforcement rod engineered as a lighter, corrosion-immune alternative to steel rebar for structural and marine concrete work. Its non-conductive, non-magnetic composition makes it the preferred choice wherever chloride exposure or electromagnetic neutrality rules out steel.
Performance Factor Haikuo FRP Rebar Steel Rebar Wood/Timber Support
Corrosion in Chloride/Saltwater Exposure Total immunity, no rust or spalling Corrodes, causes concrete spalling Rots in wet or buried conditions
Weight per Equivalent Strength Up to 75% lighter than steel Heavy, raises transport & labor cost Light but structurally weak
Electrical / Magnetic Conductivity Fully non-conductive, non-magnetic Conductive, interferes with sensitive equipment Non-conductive
Tensile Strength-to-Weight Ratio Excellent, often exceeds steel Good, but at much higher weight Poor
Long-Term Maintenance Cost Minimal, no coating needed Ongoing coating/replacement cost Frequent replacement

Targeted Product FAQ

Q1: Can FRP rebar fully replace steel rebar in load-bearing concrete structures?

A1: Yes, for most non-seismic structural and marine applications engineers now specify FRP rebar as a direct structural replacement, sized to the same design codes used for steel (with adjusted bar diameter/spacing for FRP’s different elastic modulus). We work with your engineer to confirm the right diameter and layout for your project.

Q2: Is FRP rebar safe to bend or cut on-site like steel?

A2: FRP rebar cannot be field-bent like steel — bent shapes (stirrups, hooks) must be pultruded to the final shape at the factory. Straight lengths can be cut on-site with standard diamond or abrasive blades; we recommend confirming your bent-shape requirements before ordering so we produce them correctly.

Q3: Does FRP rebar bond properly with concrete?

A3: Yes. Our rebar is manufactured with a sand-coated or ribbed surface finish specifically to maximize mechanical bond strength with concrete, matching or exceeding the bond performance of deformed steel bar.

Q4: What diameters and lengths are available?

A4: Standard diameters and custom lengths are available to match your structural drawings — see the Customized Service options above, or send us your specification and we’ll confirm availability and lead time.

Q5: Is FRP rebar suitable for both new construction and repair/retrofit work?

A5: Yes, it’s used in both — new marine and coastal structures where steel corrosion is a known risk, and repair/retrofit projects where non-conductive, lightweight reinforcement simplifies handling and installation.

Production Process

  • Pultrusion Profile Equipment

    Pultrusion Profile Equipment

  • Fiberglass placed on a shelf

    Fiberglass placed on a shelf

  • Profile mold debugging

    Profile mold debugging

  • Profile cutting

    Profile cutting

  • Profile punching

    Profile punching

  • Profile cutting details control

    Profile cutting details control

  • Profile inspection

    Profile inspection

  • Profile packaging

    Profile packaging

Certificate

  • Guangdong Haikuo Business License
  • ISO 9001 Quality Management Certificate
  • SGS Test Report — RoHS Compliance
  • SGS Test Report — RoHS Compliance
  • SGS Test Report — ASTM F963 / Prop 65
  • SGS Test Report — ASTM F963 / Prop 65
  • Fiberglass Rebar CNAS Test Report

Get Quote & Solution

Tell us the application, profile size and estimated quantity — our team will reply within 24 hours.

Ready to discuss your FRP project?

Tell us your specifications — our team replies with a quote within 24 hours.

Email Us Now